acumulator-shop.ro

miercuri, 28 august 2013

Acumulator Plumb 6V 7.0AH (SLA) Tenergy (TB670)



Product Description
6 Volt 7Ah Sealed Lead Acid Rechargeable Battery - valve regulated, which fixes the acid electrolyte in absorptive fiberglass. Product is designed to be used in close proximity with people and sensitive equipment.
Features:
  • 6 Volt 7Ah Sealed Lead Acid Rechargeable Battery.
  • Popular for multiple purpose applications.
  • Ease of use - battery is easily replaced.
  • Maintenance free from battery storage.
  • Use ABS plastic shell and valve technology.
  • Specially designed with safe and secure features.
  • Great for emergency backup power supplies.
  • Comply with environmentally friendly requirement.
  • Long service life-cycle.
  • Battery comes with full power straight from the factory.
  • No memory effect - no need to discharge and recharge battery.
Applications:
  • Uninterruptable Power Supply (UPS)
  • Electric Power System (EPS)
  • Emergency backup power supply
  • Emergency light
  • Railway signal
  • Aircraft signal
  • Alarm and security system
  • Electronic apparatus and equipment
  • Communication power supply
  • DC power supply
  • Auto control system
Specifications:
Nominal Voltage 6V
Nominal Capacity (20HR) 7AH
Dimension Length 151±1mm
Width 34±1mm
Container Height 94±1mm
Total Height 100±2mm
Approx. Weight 1.16 kg
Container Material ABS
Rated Capacity 7.0 AH/ 350 mA 20hr,5.25V/cell, 25˚C/77˚F
6.44 AH/ 644 mA 10hr,5.25V/cell, 25˚C/77˚F
5.95 AH/ 1190 mA 5hr,5.25V/cell, 25˚C/77˚F
4.2 AH/ 4200mA 1hr,4.8V/cell, 25˚C/77F˚
Internal Resistance Approx. 15~25mΩ
Operating Temp. Range Discharge -20~50˚C
Charge 0~40˚C
Storage -20~45˚C
Nominal Operating Temp. Range 25±5˚C
Cycle Use discharge at 0.25C20 (1.75A) for 2 hours
charge at constant current 0.1C20 (0.7A) for 6 hours.
Charge When ambient temperature increase/decrease 1℃,the charge voltage decrease /increase 9mV/pcs
Storage Limit Below 20˚C 9 months
20˚C ~ 30˚C 6 months
30˚C ~ 40˚C 3 months
Self Discharge Tenergy LP series batteries may be stored for up to 6 months at 25˚C(77˚F) and then a freshening charge is required. For higher temperatures the time interval will be shorter.


Acumulator 6V 4.5AH (LP6-4.5) stationar plumb


Product Description
6 Volt 4.5Ah Sealed Lead Acid Rechargeable Battery - valve regulated, which fixes the acid electrolyte in absorptive fiberglass. Product is designed to be used in close proximity with people and sensitive equipment.
Features:
  • 6 Volt 4.5Ah Sealed Lead Acid Rechargeable Battery.
  • Popular for multiple purpose applications.
  • Ease of use - battery is easily replaced.
  • Maintenance free from battery storage.
  • Use ABS plastic shell and valve technology.
  • Specially designed with safe and secure features.
  • Great for emergency backup power supplies.
  • Comply with environmentally friendly requirement.
  • Long service life-cycle.
  • Battery comes with full power straight from the factory.
  • No memory effect - no need to discharge and recharge battery.




Applications:
  • Replacement Biomedical Battery for Hospira Inc Plum A Plus Infusion Pump. 
  • Uninterruptable Power Supply (UPS)
  • Electric Power System (EPS)
  • Emergency backup power supply
  • Emergency light
  • Railway signal
  • Aircraft signal
  • Alarm and security system
  • Electronic apparatus and equipment
  • Communication power supply
  • DC power supply
  • Auto control system
Specifications:
Nominal Voltage 6V
Nominal Capacity (20HR) 4.5AH
Dimension Length 70±1mm (2.76 inches)
Width 47±1mm (1.85 inches)
Container Height 100±2mm (3.94 inches)
Total Height (w/ Terminal) 106±2mm (4.17 inches)
Approx. Weight 0.81kg (1.79lbs)
Terminal T1
Container Material ABS
Rated Capacity 4.5 AH/0.225A 20hr,1.8V/cell,25˚C/77˚F
4.19 AH/0.419A 10hr,1.8V/cell,25˚C/77˚F
3.85 AH/0.77A 5hr,1.75V/cell,25˚C/77˚F
3.45 AH/1.15A 3hr,1.75V/cell,25˚C/77˚F
2.83 AH/2.83A 1hr,1.60V/cell,25˚C/77F˚
Max. Discharge Current 67.5A (5s)
Internal Resistance Approx. 25mΩ
Operating Temp. Range Discharge -15~50˚C (5~122˚F)
Charge 0~40˚C (32~104˚F)
Storage -15~40˚C (5~104˚F)
Nominal Operating Temp. Range 25±3˚C (77±5˚F)
Cycle Use Initial Charging Current less than 1.35A. Voltage 7.2V~7.5V at 25˚ C (77˚F) Temp. Coefficient -15mV/˚C
Standby Use No limit on Initial Charging Current Voltage 6.75V~6.9V at 25˚C(77˚F) Temp. Coefficient -10mV/˚C
Capacity affected by Temperature 40˚C (104˚F) 103%
25˚C (77˚F) 100%
0˚C (32˚F) 86%
Self Discharge Tenergy LP series batteries may be stored for up to 6 months at 25˚C(77˚F) and then a freshening charge is required. For higher temperatures the time interval will be shorter.







Acumulator VRLA Plumb 12V 20AH (LP12-20) (SLA)



Product Description
12 Volt 20Ah Sealed Lead Acid Rechargeable Battery - valve regulated, which fixes the acid electrolyte in absorptive fiberglass. Product is designed to be used in close proximity with people and sensitive equipment.
Features:
  • 12 Volt 20Ah Sealed Lead Acid Rechargeable Battery.
  • Popular for multiple purpose applications.
  • Ease of use - battery is easily replaced.
  • Maintenance free from battery storage.
  • Use ABS plastic shell and valve technology.
  • Specially designed with safe and secure features.
  • Great for emergency backup power supplies.
  • Comply with environmentally friendly requirement.
  • Long service life-cycle.
  • Battery comes with full power straight from the factory.
  • No memory effect - no need to discharge and recharge battery.
Applications:
  • Uninterruptable Power Supply (UPS)
  • Electric Power System (EPS)
  • Emergency backup power supply
  • Emergency light
  • Railway signal
  • Aircraft signal
  • Alarm and security system
  • Electronic apparatus and equipment
  • Communication power supply
  • DC power supply
  • Auto control system
Specifications:
Nominal Voltage 12V
Nominal Capacity 20AH
Dimension Length 181.5±1mm (7.14 inches)
Width 77±1mm (3.03 inches)
Container Height 167.5±1mm (6.59 inches)
Total Height (w/ Terminal) 167.5±1mm (6.59 inches)
Approx. Weight 5.78 kg (12.74lbs)
Terminal T3 / T12
Container Material ABS
Rated Capacity 20 AH/1.00A 20hr,1.8V/cell,25˚C/77˚F
18.6 AH/1.86A 10hr,1.8V/cell,25˚C/77˚F
17.0 AH/3.40A 5hr,1.75V/cell,25˚C/77˚F
15.3 AH/5.10A 3hr,1.75V/cell,25˚C/77˚F
12.56 AH/12.56A 1hr,1.60V/cell,25˚C/77F˚
Max. Discharge Current 300A (5s)
Internal Resistance Approx. 15mΩ
Operating Temp. Range Discharge -15~50˚C (5~122˚F)
Charge 0~40˚C (32~104˚F)
Storage -15~40˚C (5~104˚F)
Nominal Operating Temp. Range 25±3˚C (77±5˚F)
Cycle Use Initial Charging Current less than 6.0A. Voltage 14.4V~15.0V at 25˚ C (77˚F) Temp. Coefficient -30mV/˚C
Standby Use No limit on Initial Charging Current Voltage 13.5V~13.8V at 25˚C(77˚F) Temp. Coefficient -20mV/˚C
Capacity affected by Temperature 40˚C (104˚F) 103%
25˚C (77˚F) 100%
0˚C (32˚F) 86%
Self Discharge Tenergy LP series batteries may be stored for up to 6 months at 25˚C(77˚F) and then a freshening charge is required. For higher temperatures the time interval will be shorter.










Acumulator plumb 12V 9AH (SLA) Battery




Product Description
12 Volt 9Ah Sealed Lead Acid Rechargeable Battery - valve regulated, which fixes the acid electrolyte in absorptive fiberglass. Product is designed to be used in close proximity with people and sensitive equipment.
Features:
  • 12 Volt 9Ah Sealed Lead Acid Rechargeable Battery.
  • Popular for multiple purpose applications.
  • Ease of use - battery is easily replaced.
  • Maintenance free from battery storage.
  • Use ABS plastic shell and valve technology.
  • Specially designed with safe and secure features.
  • Great for emergency backup power supplies.
  • Comply with environmentally friendly requirement.
  • Long service life-cycle.
  • Battery comes with full power straight from the factory.
  • No memory effect - no need to discharge and recharge battery.



Applications:
  • Uninterruptable Power Supply (UPS)
  • Electric Power System (EPS)
  • Emergency backup power supply
  • Emergency light
  • Railway signal
  • Aircraft signal
  • Alarm and security system
  • Electronic apparatus and equipment
  • Communication power supply
  • DC power supply
  • Auto control system
Specifications:
Nominal Voltage 12V
Nominal Capacity (20HR) 9AH
Dimension Length 151±1mm (5.95 inches)
Width 65±1mm (2.57 inches)
Height 95±1mm (3.74 inches)
Total Height (w/ Terminal) 100±2mm (3.96 inches)
Approx. Weight 2.7±0.1kg(5.96lbs)
Terminal T1
Container Material ABS
Rated Capacity 9.0 AH/0.45A 20hr,10.5V/cell,25˚C/77˚F
8.1AH/0.81A 10hr,10.5V/cell,25˚C/77˚F
7.2AH/1.44A 5hr,10.5V/cell,25˚C/77˚F
4.8AH/4.8A 1hr,9.60V/cell,25˚C/77F˚
Internal Resistance Approx.15~25mΩ
Operating Temp. Range Discharge -20~50˚C (-4~122˚F)
Charge 0~40˚C (32~104˚F)
Storage -20~40˚C (-4~104˚F)
Nominal Operating Temp. Range 25±5˚C (77±5˚F)
Cycle Use Charge Initial Charging Current less than 2.7A. Voltage 14.6V~15.0V at 25˚ C (77˚F) Temp. Coefficient -18mV/˚C
Float Charge Initial Charging Current less than 2.7A. Voltage 13.5V~13.8V at 25˚C(77˚F) Temp. Coefficient -18mV/˚C
Storage Limit Below 20˚C (68˚F) 9 months
20~30˚C (68~86˚F) 6 months
30~40˚C (86~104˚F) 3 months
Self Discharge
(ambient temperature:25±5˚C)
1)3 months after fully charge,the capacity conservation shall not less than 80%.
2)6 months after fully charge,the capacity conservation shall not less than 60%.

Acumulator UPS 12V 4ah/5Ah plumb acid

Sunlight Acumulatori Etansi VRLA 12V-5 Ah Sunlight Cod produs: SP 12-5 , Acumulator Baterie Yuasa NP 4-12 12v / 4Ah. Model: NP 4-12 Tip: Acid-Plumb

Acumulator 12v 4ah/5ah plumb acid


Pret de magazin - Acumulator 12v 5ah plumb acid





duminică, 25 august 2013

12V 20AH Sealed Lead Acid (SLA) Battery

12V 20AH (LPX12-20) Maintenance-free Sealed Lead Acid (SLA) Battery

All Power Tool Batteries 15% off with code "powertool"


12 Volt 20Ah Sealed Lead Acid Rechargeable Battery - valve regulated, which fixes the acid electrolyte in absorptive fiberglass. Product is designed to be used in close proximity with people and sensitive equipment.
Features:
  • 12 Volt 20Ah Sealed Lead Acid Rechargeable Battery.
  • Popular for multiple purpose applications.
  • Ease of use - battery is easily replaced.
  • Maintenance free from battery storage.
  • Use ABS plastic shell and valve technology.
  • Specially designed with safe and secure features.
  • Great for emergency backup power supplies.
  • Comply with environmentally friendly requirement.
  • Long service life-cycle.
  • Battery comes with full power straight from the factory.
  • No memory effect - no need to discharge and recharge battery.
Applications:
  • Uninterruptable Power Supply (UPS)
  • Electric Power System (EPS)
  • Emergency backup power supply
  • Emergency light
  • Railway signal
  • Aircraft signal
  • Alarm and security system
  • Electronic apparatus and equipment
  • Communication power supply
  • DC power supply
  • Auto control system
                                                                          


Specifications:
Nominal Voltage12V
Walts (15min Rate)82.7 Watts at 1.67V/cell
DimensionLength181.5±1mm (7.14 inches)
Width77±1mm (3.03 inches)
Container Height167.5±1mm (6.59 inches)
Total Height (w/ Terminal)167.5±1mm (6.59 inches)
Approx. Weight6.6 kg (14.6lbs)
TerminalT3 / T12
Container MaterialABS
Rated Capacity20.4 AH/2.04A10hr,1.8V/cell,25˚C/77˚F
20.0 AH/2.50A8hr,1.8V/cell,25˚C/77˚F
18.5 AH/3.71A5hr,1.75V/cell,25˚C/77˚F
17.1 AH/5.69A3hr,1.75V/cell,25˚C/77˚F
16.7 AH/16.7A1hr,1.60V/cell,25˚C/77F˚
Max. Discharge Current300A (5s)
Internal ResistanceApprox. 15mΩ
Operating Temp. RangeDischarge-15~50˚C (5~122˚F)
Charge0~40˚C (32~104˚F)
Storage-15~40˚C (5~104˚F)
Nominal Operating Temp. Range25±3˚C (77±5˚F)
Cycle UseInitial Charging Current less than 6.0A. Voltage 14.4V~15.0V at 25˚ C (77˚F) Temp. Coefficient -30mV/˚C
Standby UseNo limit on Initial Charging Current Voltage 13.5V~13.8V at 25˚C(77˚F) Temp. Coefficient -20mV/˚C
Capacity affected by Temperature40˚C (104˚F)103%
25˚C (77˚F)100%
0˚C (32˚F)86%
Self DischargeTenergy LP series batteries may be stored for up to 6 months at 25˚C(77˚F) and then a freshening charge is required. For higher temperatures the time interval will be shorter.










sâmbătă, 24 august 2013

Acumulator 12v 12ah - Plumb Acid

acumulator plumb 12V 12A globstar.ro

Baterii acide cu plumb, sigilate, reincarcabile, cu valva regulatoare. Utilizeaza tehnologia AGM si sunt realizate cu placi PbCa-Sn si electrolit de inalta puritate care permite obtinerea unui surplus de putere. Aceste baterii sunt ideale pentru aplicatii in domeniul UPS de mica putere, sisteme de iluminat de siguranta si sisteme de putere de rezerva (backup).


              Pret - Acumulator Pentru UPS cu Plumb VRLA 12v 12Ah.


Dimensiuni: L 151 mm.

                     l 98 mm.

                     h 95 mm.

 

Utilizari : Sisteme UPS ,centrale telefonice ,scutere ,barcute nadit etc.